Jun 6, 2019

Wiring Multiple Choice Questions And Answers In English -03



1. …………. gives a diversion of 90 degree in the turn of a conduit
(A) Couplers
(B) Elbow
(C) Bends
(D) Tees
Answer- (C) Bends

2. ………….are used to take diversion from the main line either to the switch points at light points.
(A) Couplers
(B) Elbow
(C) Bends
(D) Tees
Answer- (D) Tees
3. Small circular boxes shall be provided with two machine screws of a diameter not less than …………. mm for fixing the covers
(A) 4
(B) 8
(C) 0
(D) 9
Answer- (B) 8

4. Large circular boxes shall be provided with two machine screws of a diameter not less than …………. mm for fixing the covers
(A) 4
(B) 8
(C) 0
(D) 9
Answer- (C) 0

5. The most common joining conduits with fitting uses ………….
(A) Gum
(B) Hacksaw frame
(C) Solvent adhesive
(D) All the above
Answer- (C) Solvent adhesive

6. PVC conduits not exceeding ………….mm diameter can be bent cold by using a spring
(A) 50
(B) 30
(C) 25
(D) 45
Answer- (C) 25

7. Cold bending could be done using a ………….
(A) Spring
(B) Hack saw frame
(C) Hand
(D) Knee
Answer- (A) Spring

8. Factors to select the correct size of conduit depends on………….
(A) Size of cables
(B) Number of cables to be drawn
(C) Both a & b
(D) None of these
Answer- (C) Both A & B

9. When (B)5 sq. mm 640 V grade single core cables of six numbers are to be drawn in a single run, we can use ………….non-metallic conduit
(A) 25
(B) 30
(C) 40
(D) 50
Answer- (A) 25

10. ………….can be inserted inside the conduit to pull the cables
through the conduits
(A) GI
(B) Draw wire
(C) Both A & B
(D) None of these
Answer- (C) Both A & B


11. Rigid PVC conduits are not suitable for use where the normal working temperature of the conduits and fittings may exceed ……degree C
(A) 60
(B) 70
(C) 65
(D) 55
Answer- (D) 55

12. …………. wiring is a system of wiring in which PVC channels with covers are used for drawing wires
(A) Cleat
(B) Batten
(C) PVC
(D) Channel
Answer- (D) Channel

13. The number of socket outlets of 5A in bedroom are ………….
(A) 2 to 3
(B) 1
(C) 4
(D) 5
Answer- (A) 2 to 3

14. How many 15 A socket outlets are needed in kitchen
(A) 1
(B) 2
(C) 3
(D) 4
Answer- (B) 2

15. For surface wiring system, however work should begin before final finishing work like ………….
(A) White washing
(B) after plating
(C) after painting
(D) after ignoration
Answer- (A) White washing

16. Each circuit shall be provided with a ....in the phase wire and the neutral conductor shall be connected to a common link with disconnecting arrangement for testing.
(A) Fuse
(B) Socket
(C) Switch
(D) All the above
Answer- (A) Fuse

17. The load on the light and fan sub circuits should be restricted to
………….
(A) 600 watts
(B) 800 watts
(C) 700 watts
(D) 1000 watts
Answer- (B) 800 watts

18. Incandescent lamps have …………. rating
(A) 60 watts
(B) 100 watts
(C) 25 watts
(D) 90 watts
Answer- (A) 60 watts

19. If we have 2 5A sockets of 100 watts each then the load in light circuit is
………….
(A) 200
(B) 60
(C) 1000
(D) 500
Answer- (A) 200

20. Load in light circuit of 2, 5A (100 watt) 1 Lamp (60 watt ) and 1 ceiling fan(60 watt) is ………….W
(A) 240
(B) 530
(C) 320
(D) 400
Answer- (C) 320