Jun 5, 2019

Wiring Multiple Choice Questions And Answers In English -02



1. To relieve the strain from the terminals of pendants, lamp holders and ceiling roses ………….are used.
(A) Cord grip
(B) Underwriters knot
(C) Both a & b
(D) None of these
Answer- (C) Both a & b

2. Cord grip and under writers knot are used in………….
(A) Lamp holders terminals
(B) Ceiling roses
(C) Terminals of pendants
(D) All of these
Answer- (D) All of these
3. In………….the phase or line conductor shall be looped at
the switch box and neutral conductors at the point outlets
(A) Looping back method
(B) Looping in method using 2 plate ceiling roses and switches
(C) Looping in method using 2 plate ceiling roses and switches
(D) Joint box method
Answer- (A) Looping back method

4.  In the………….method, wherever tapping must be taken from cable, joints are made
(A) Looping back method
(B) Looping in method using 2 plate ceiling roses and switches
(C) Looping in method using 2 plate ceiling roses and switches
(D) Joint box method
Answer- (D) Joint box method

5. …………. cables are used suitable to run on teak wood battens
(A) TRS
(B) Tough Rubber Sheathed
(C) PVC sheathed
(D) All of these
Answer- (D) All of these

6. ………….wiring is used to draw TRS cables on Teak wood
(A) Cleat
(B) Batten
(C) PVC
(D) All of these
Answer- (B) Batten

7. The intervals between wood plugs in batten wiring should at intervals not exceeding………….cm
(A) 60
(B) 65
(C) 70
(D) 75
Answer- (D) 75

8. ………….are used for firmly clipping the cables in position during batten wiring
(A) Knot
(B) Clamps
(C) Link cables
(D) Cable tags
Answer- (C) Link cables

9. Link clips are packed in card board boxes at the rate of ………….link clips per box
(A) 200
(B) 300
(C) 100
(D) 500
Answer- (C) 100

10. The load on the light and fan sub circuits should be restricted to………
(A) 600 watts
(B) 800 watts
(C) 700 watts
(D) 1000 watts
Answer- (B) 800 watts
11. Which amongst the following is not a Nominal size of conduit in mm
(A) 20
(B) 25
(C) 38
(D) 50
Answer- (D) 50

12. For surface wiring system, however work should begin before final finishing work like …………….
(A) White washing
(B) after plating
(C) after painting
(D) after ignoration
Answer- (A) White washing

13. PVC conduits are available on …………. m length
(A) 2
(B) 4
(C) 3
(D) 5
Answer- (C) 3

14. ………….conduits are used for protecting cable ends connected to a vibrating machine inter connection between switch gear and distribution boards
(A) Rigid steel conduits
(B) Rigid non-metallic conduits
(C) Flexible conduits
(D) TRS wiring
Answer- (C) Flexible conduits

15. ………….conduit wiring system done on wall surfaces
(A) Surface
(B) Concealed
(C) Recessed
(D) All the above
Answer- (A) Surface

16. ………….conduit wiring system done inside the concrete plaster or wall
(A) Surface
(B) Concealed
(C) Recessed
(D) Both b & C
Answer- (A) Surface

17. Selection of the type of conduit depends upon the………….
(A) Type of location, outdoor or indoor
(B) Type of atmosphere and estimated cost
(C) Expected working temperature & allowable weight of conduit runs
(D) All the above
Answer- (D) All the above

18. ………….are used where the conduits shall be pushed right through to the interior of the fittings
(A) Couplers
(B) Elbow
(C) Bends
(D) Tees
Answer- (A) Couplers

19. ………….types couplers are used in straight conduit runs to assit in the inspection of the cables
(A) Couplers
(B) Elbow
(C) Bends
(D) Tees
Answer- (A) Couplers

20. …………. are used at sharp ends of nearby walls or roofs and wall
(A) Couplers
(B) Elbow
(C) Bends
(D) Tees
Answer- (B) Elbow
||Electrical Wiring Multiple Choice Questions And Answers||